C+ + O2 → CO + O+
Type: Ion-neutral
Alpha: 4.54e-10
Beta: 0.00
Gamma: 0.00
Temperature range: 10 - 41000 K
Accuracy: within 25%
Source: Measurement
Reference: View
UDfA History
Database | Index | α | β | γ | Tl - Tu (K) | Accuracy | Source |
---|---|---|---|---|---|---|---|
RATE12 | 1644 | 4.54e-10 | 0.00 | 0.00 | 10 - 41000 | within 25% | Measurement |
RATE06 | 1235 | 6.20e-10 | 0.00 | 0.00 | 10 - 41000 | within 25% | Measurement |
Reference: Smith, D. and Adams, N.G., Int. J. Mass Spectrom. Ion Phys., 23, 123 (1977); Smith, D. and Adams, N.G., Chem. Phys. Lett., 47, 383 (1977). | |||||||
RATE99 | 1079 | 6.20e-10 | 0.00 | 0.00 | 10 - 41000 | within 25% | Measurement |
Reference: Smith, D. and Adams, N.G., Int. J. Mass Spectrom. Ion Phys., 23, 123 (1977); Smith, D. and Adams, N.G., Chem. Phys. Lett., 47, 383 (1977). | |||||||
RATE95 | 1118 | 6.20e-10 | 0.00 | 0.00 | 0 - 0 | within 25% | Measurement |
Reference: Smith, D. and Adams, N.G., Int. J. Mass Spectrom. Ion Phys., 23, 123 (1977); Smith, D. and Adams, N.G., Chem. Phys. Lett., 47, 383 (1977). |