O+ + C2H4 → C2H2+ + H2O
Type: Ion-neutral
Alpha: 1.12e-9
Beta: 0.00
Gamma: 0.00
Temperature range: 10 - 41000 K
Accuracy: within 25%
Source: Measurement
Reference: D. Smith, P. Spanel and C. A. Mayhew, A selected ion-flow tube study of the reactions of O+, H+ and HeH+ with several molecular gases at 300 K, Int. J. Mass Spectrom. Ion Proc., 117, 457-473(1992). View
UDfA History
Database | Index | α | β | γ | Tl - Tu (K) | Accuracy | Source |
---|---|---|---|---|---|---|---|
RATE12 | 3853 | 1.12e-9 | 0.00 | 0.00 | 10 - 41000 | within 25% | Measurement |
Reference: D. Smith, P. Spanel and C. A. Mayhew, A selected ion-flow tube study of the reactions of O+, H+ and HeH+ with several molecular gases at 300 K, Int. J. Mass Spectrom. Ion Proc., 117, 457-473(1992). | |||||||
RATE06 | 1735 | 1.12e-9 | 0.00 | 0.00 | 10 - 41000 | within 25% | Measurement |
Reference: D. Smith, P. Spanel and C. A. Mayhew, A selected ion-flow tube study of the reactions of O+, H+ and HeH+ with several molecular gases at 300 K, Int. J. Mass Spectrom. Ion Proc., 117, 457-473(1992). | |||||||
RATE99 | 1556 | 1.40e-9 | 0.00 | 0.00 | 10 - 41000 | within 25% | Measurement |
Reference: Smith, Spanel & Mayhew, 1992, Int. J. Mass Spectrom. Ion. Proc., 117, 457. | |||||||
RATE95 | 1538 | 1.40e-9 | 0.00 | 0.00 | 0 - 0 | within 25% | Measurement |
Reference: Smith, Spanel & Mayhew, 1992, Int. J. Mass Spectrom. Ion. Proc., 117, 457. |